STAGE

  • Proscenium Stage – Flat
  • Proscenium Opening – 12.44m
  • Proscenium Height – 6.87m
  • Depth From Iron to Cyclorama – 8.84m (With Cyc. at furthest upstage hemp-set)
  • Width of Backstage Area – 15.54m
  • Depth of Backstage Area – 4.88m
  • Grid Steel Height – 18.29m
  • Wing Width from Onstage Fly-rail – 5.18m
  • Maximum Working Height of Scenery – 6.01m
  • Width of Counterweight Flying Bars – 12.2m / 12.4m
  • Number of Counterweight Bars – 30
    • House Tabs normally occupies Counterweight  # 1
    • House Border normally occupies Counterweight  # 2
    • Cinema Screen normally occupies Counterweight # 5
      (9.35m Wide by 4.35m Drop)
  • Max load per bar – 250kg
  • Prompt Corner Located Stage Left
  • Pass Door to Front of House – Stage Right
  • Get-in Doors Stage Left – approx. 3.5m (W) X 3.35m (H) – 1.2m drop to street level
  • Ramp – 1 by 14ft Aluminium Load in ramp
  • Trap – Mid-Stage ( 0.9m X 0.9m with counterweighted elevator trap)

 

Please use the above as a guide only and refer to current floor plans and/or site visits for actual dimensions

We have a permanently flown 9.75m x 5.49m cinema screen – this normally occupies c/w # 5 but can be moved to another bar with sufficient notice.

 

DRESSING ROOM

  •  7 Rooms in total
  • 6 at first floor level and 1 at second floor level
  • 2 En Suite with Showers
  • 1 with Shower only

LAUNDRY

  • 1 x Top loader Washing Machine (semi-industrial)
  • 1 x Tumble Dryer (semi-industrial)

 

ORCHESTRA PIT

  •  Accommodates up to 25 players
  • Can be extended into auditorium to accommodate 70 players
  • Music stands can be hired locally
  • Piano can be hired locally
  • Limited chairs available
  • Piano – We do not have an in-house piano. Pianos can be hired at a  cost.

 

ELECTRICS

Lanterns

  • 10 X Cantata F – 1.2kW Fresnels – Beam Angle 8/50°
  •  24 X Robert Juliat 310 HF – 1.2kW Fresnels – Beam Angle 6/46°
  •  3 X Strand 243 (Retrofitted) – 2kW Fresnel – Beam Angle 15/50°
  •  50 X PAR 64 (various beamwidths) – 1kW PAR
  • 12 X PAR 64 Floor PAR’s (various beamwidths) – 1kW PAR
  •  2 X Cantata 18/32 – 1.2kW Zoom Profiles – Beam Angle 18/32°
  •  3 X Cantata 11/26 – 1.2kW Zoom Profiles – Beam Angle 11/26°
  •  1 X ETC Source 4 50° – 575W Profiles – Beam Angle 50°
  •  12 X ETC Source 4 26° – 575W Profiles – Beam Angle 26°
  •  14 X ETC Source 4 36° – 750W Profiles – Beam Angle 36°
  •  18 X ETC Source 4 Zoom – 750W Zoom Profiles – Beam Angle 15/30°
  •  1 X ETC Source 4 Zoom – 750W Zoom Profiles – Beam Angle 25/50°
  •  24 X Spotlight Domino Single Cyclorama Flood 1kW
  •  10 X Showtech Sunstrip Active DMX

Followspots

  • 2 X Robert Juliat Topaze 1,200W MSD

 

Lighting Control And Dimming

  • ETC Gio 2000 Channel
  • ETC Ion 1000 Channel
  •  ETC Net3 Four Port Gateway w/ 4 x DMX Outputs
  •  Avolites Arena
  •  156 X 3kW ETC Sensor Dimmers
  •  36 X 5kW ETC Sensor Dimmers

Please note that all 3kW dimmer outlets are 16A CEE Type and 5kW outlets are 32A CEE type connectors. Limited number of 16A-to-15A adaptors are available. Pre-Wired Bars and Dips are fed from 6-way Socapex connectors – Please see included circuit layout diagram for more details 

 

Additional Equipment – May be Subject to Availability and/or Hire Charges

  • 8 X Prolights Luma 700 LED Spot
  •  8 X Prolights Diamond LED Wash
  •  8 X Generic RGBW LED Pars
  •  8 X Generic RGBWAUV Zoom LED Pars
  •  12 X Chroma Q CQ1D 16-frame Colour Scroller
  •  2 X Rainbow 8” Pro 16-frame Colour Scroller
  •  1 x Rainbow MAXI 4 PSU
  •  1 x Chroma Q PS08 PSU
  •  1 X Unique Mk1 DMX Haze Machine
  •  4 X Jem Magnum 1500 w/ DMX Control

Colour Filters are not supplied by theatre.

Rigging & Miscellaneous Equipment – May Be To Subject to Availability And/Or Hire Charges

  • 4 X Fixed Base Booms – approx. 5m each
  • 4 X Steel Boom Bases
  • 4 X MDF Boom Bases
  • Boom Poles of various height
  • Various boom arms, rigging accessories, etc.

Please note that the use of certain rigging equipment requires a qualified rigger to be present for set-up and take-down

Mains Supplies

  • 1 X 250A 3-Phase Supply Located USR – Powerlock
  • 1 X 63A 3-Phase Supply Located DSR (3  63A CEE Type Connector)
  • 1 X 32A 3-Phase Supply Located DSR (3  32A CEE Type Connector)
  • 2 X 32A Single Phase Supplies Located DSR
  • 2 X 32A Single Phase Supplies Located DSL
  • Various 16A, 15A and 13A supplies

Audio Supply – All Located DSL

  •  4 X 13A Single Phase (13A Sockets)
  •  1 X 15A Single Phase (15A Socket)
  •  3 X 16A Single Phase (CEE Type Sockets)
  •  6 X 32A Single Phase (CEE Type Sockets)
  •  1 X 63A Single Phase (Tails Only)
  •  1 X 63A Three Phase (CEE Type Socket)

Access Equipment

Tallescope Model 50524

Maximum Working Height 9.5m (At Platform Height 7.5m)
Minimum Platform Height 4.7m

Aluminium 3 Section Combination Ladder (3×12 Rung Zarges Type)

Maximum Working Height 7.01m
Maximum Working Height (Used as 3-Piece Lean-to) 9.56m

 

SOUND SYSTEM

FULL SYSTEM – MAY BE SUBJECT TO ADDITIONAL HIRE CHARGES

Digital Consoles

  • Yamaha QL5 (32ch + 16 out) +Yamaha Rio 3224-D (32ch+16 out)= 64ch + 24 out
  • Yamaha PM5D (48ch + 4 Stereo) – Normally Monitor Console
  •  Yamaha DM2000 (56ch + 24 line (4x AD8HR 8-way digital preamps))
  • Yamaha LS9-32
  •  Yamaha O1V96 (12ch + 4 line)
  • FOH Rack
  •  1 X BSS 31 band EQ
  •  1 X Yamaha REV500
  •  2 X Yamaha SPX 2000
  •  1 X T.C. electronic D-TWO Multi Tap Rhythm Delay
  •  4 X XTA C2 dual compressors
  •  4 X XTA G2 dual gates
  •  4 X dbx 166 dual comp/gate
  •  1 X Gemini CD Player
  •  1 X Tascam MD-350 mini disk player

Multi Core System

  •  2 X 48 in 192 out XTA DS800 active splitter
  • 2 X 12ch Returns from FOH (passive)
  •  1 X 24ch + 12 Rtns (control room to Stage left – Passive)

Microphones

  •  10 X Shure SM58
  •  2 X Audix OM6
  •  2X Sennhiser E935
  •  2 X Shure Beta 58A
  •  2 X Shure SLX / Beta 87A Wireless Handheld Set
  •  10 X Shure SM57
  •  2 X Sennhiser e906
  •  3 X Shure SM86
  •  1 X Shure Beta 57A
  •  1 X Shure Beta 52A
  •  1 X Audix D6
  •  1X AKG D112
  •  2 X Shure Beta 91A
  •  3 X Shure Beta 98HC
  •  6 X Shure Beta 98AD
  •  6 X Sennhiser 604’s
  •  1 X DPA d:vote 4099 (Cello Clip, Violin Clip, Piano Clip)
  •  2 X Shure SM81 (Matched pair)
  •  4 X AKG 451 (2 by matched pairs)
  •  2 X Oktava MK 012-01 MSP2 ( Matched pair)
  •  2 X M-Audio Nova Large diaphragm
  •  1 X SE 2000 Large Diaphragm
  •  3 X AKG 568C (Rifle Mics)
  •  2 X AKG Perception 150
  •  4 X BSS Active DI boxes
  •  2 X Palmer Passive Stereo (dual) DI Boxes
  •  5 X Klark Teknik DI Boxes
  •  2 X Radial Pro Passive DI
  •  2 X Radial Pro 48 Active DI

SPEAKER SYSTEM

PA

  •  16 X Martin Audio W8LM Line Array 8 boxes up stairs and 8 boxes down stairs.
    (The up stairs Line Array is Dead Hung and cannot be moved)
  • 4 X Martin Audio WLXG Subs

Centre fills

  • 4 X Martin AQ5’s

Balcony fills

  • 2 x Martin F-15’s

Box Fills

  • 2 X Martin AQ5’s

Surround System

  • 4 X Martin F-10 Blackline (2 stalls & 2 balcony)

FOLD BACK

Monitors

  • 12 X Martin LE12JB Bi-amped

Drum Fill

  • 1 x Martin F215 (Dual 15″)
  • 1 x Martin S18 sub

AMPLIFICATION

Wedge Monitor Amplification
Martin Audio E1300 series

 

PYROTECHNICS – Regulatory Controls & Licensing

NB Use of the Pyrotechnics is strictly controlled and is subject to license by the Department of Justice and the local authority.

  • Lockable steel-frame sagfe/strong box for storage

 

COMMUNICATIONS

  • Tecpro Ring Intercom System
  • Master Station at Prompt Corner
  • 8 X Belt Pack units with Head Sets
  • Show Relay and Dressing-room/Backstage calls system
  • ASL 12-Channel Cue Light System w/ 12 X Outstations

Show Relay

  • Microphone on proscenium relayed to outlets throughout backstage area
  • Currently one in each dressing room, one in Green Room and one in Control Room.

 

AUDIO-VISUAL EQUIPMENT May Be To Subject to Availability And/Or Hire Charges

  • 2 X 21” Video Monitors (Composite/S-Video Input)
  •  2 X Composite Video Distribution Amplifiers
  •  2 X 4×1 Composite Video Switchers
  •  Various VGA/RG59 Cables
  •  Bluray Playback Equipment
  •  DVD Playback Equipment
  • Colour Video Camera at Circle Front for Video Relay

Contacts

Technical Manager

Chris Gaughan +353 21 4905 209
+353 86 6018517
')">

Stage Manager

 Declan O’ Mullane +353 21 4905 209
+353 86 173 8836
')">

Chief Electrician

 Drew McCarthy +353 21 4905 210
 ')">

Head Of Sound

Colm Hinchion +353 21 4905 210
')">

General Contacts

Telephone
Fax
Email
+353 21 490 5209
+353 21 427 6357
')">

 

Stage Door Direct Line

+353 21 490 5225